Ultra-High Resolution QTOF Mass Spectrometry
Accurate mass, absolute identification, assured results
​
Obtaining the most complete and true picture of a sample set is a consistent goal for scientists. Complex food or forensic sample matrices, challenging industrial formulations, and demanding multi-analyte environmental screening assays require superior sensitivity, resolution, and speed to truly understand the full nature of the sample. The outstanding dynamic range, high mass accuracy, and exceptional MS/MS performance, enable Bruker's Ultra High Resolution (UHR) QTOF MS systems to deliver confident, reliable results for both targeted analytical testing and broader research applications of unknowns. Whether running fast comprehensive environmental screens or exploring every facet of a highly complex food or industrial sample, detect screen hits of known compounds, confident, unbiased identification of unknowns and reliable quantitation on the fly. Thoughtful, comprehensive software simplifies your analytical workflow harnessing this brilliant banalytical power to make UHR QTOF MS accessible and vital for your laboratory.
ESI QTOF
Bruker’s compact, impact II VIP and maXis II QTOF mass spectrometers are the showcase instrument platform for sample characterization and screening applications involving the analysis of both targeted and non-targeted compounds in complex matrices. Built to last with minimum maintenance efforts, these systems provide the highest QTOF mass accuracy, sustained sensitivity, and enduring signal stability for cutting-edge performance in one-shot analysis. The dynamic source configuration offers extensive analytical versatility to cover all sample types from environment, food, and forensics all the way through various industrial markets.

compact
A compact platform designed for both targeted and untargeted compound analysis, offering high mass accuracy.
​
Key Features:
Resolution: 30,000 Da
Applications:
Pharmaceutical Research
Biotechnology
compact impact II VIP
Provides long-term performance with minimal maintenance.
​
Key Features:
Resolution: 60,000 Da
Applications:
Clinical Laboratories


maXis II
A revolutionary system providing rapid analysis without chromatography, ideal for food and environmental testing.
​
Key Features:
MRM Speed: 1,000 MRM/second
Mass Range: 10–1,200 Da
​
Applications:
Food Testing
Environmental Monitoring
ecTOF
Dual ionization GC-HRMS with simultaneous EI and CI
​
Absolute confidence for the identification of unknowns with less time and effort in suspect and non-target GC/MS.
​
Key Features:
Spectra Rate: minimum 100 full mass spectra/s
Mass Resolving Power: CI > 10,000, EI > 8,000
Mass Accuracy: < 3 ppm
​
Applications:
Food
Environmental
Pharma