top of page

MALDI-TOF and TOF/TOF Mass Spectrometry

Flagship FLEX series is the global leader for MALDI applications

 

Bruker's FLEX series is the absolute market leading MALDI platform. With its fully trusted innovative

design, the FLEX series sets the precedent for outstanding MALDI performance, reliability, and

convenience. Covering a broad range of applications from additive analysis to surface imaging, the

benchmark FLEX series MALDI systems are the standard for polymer analysis. These MALDI systems

include a wide range of capabilities enabling beginners and experts to achieve maximum efficiency.

Highly automated workflows enable data acquisition and in-depth analysis from the smallest amounts

of samples within seconds. Intuitive and powerful software packages support data visualization and

turn-key target characterization.

microflex series

From small molecules to polymers, the bench-top smartflex® and microflex® LRF are the perfect choice. The robust design guarantees reliable daily operation for chemical synthesis checks, lubricant quality control, additives analysis, and food adulteration analysis. Ideal for non-expert users and busy multi-instrument labs where ease-of-use, intuitive operations, and reliability are critical. While microflex LRF provides expanded capabilities for smaller molecules due to the reflector mode, the smartflex with patented smartbeam laser provides extended lifetime for high-throughput applications.

microflex-lrf-portrait1.png

microflex LRF/smartflex

Key Features:

Resolution: 15,000 (LRF)

mass range: up to 500,000

mass accuracy: 15 (int. calibration.) (ppm) (LRF)

laser: Nitrogen/smartbeam

laser frequency (Hz): 60/200 (MS)

​

autoflex maX series

Performance-leading MALDI-TOF and TOF/TOF technology enables reliable, detailed characterization of polymers and industrial synthetic chemicals. Smartbeam-II laser technology delivers superior spectral data quality with minimized sample preparation. The field-upgradable autoflex® maX is available in linear, high resolution reflectron or TOF/TOF versions spanningapplications from dyes, pigments, and colorants to cutting edge polymer applications. The TOF/ TOF versions employ LIFT and high energy CID for fast, sensitive MS/MS experiments to yield chemical structural information of the precursor molecule benefiting polymer recycling and upcycling applications.

autoflex maX (LIN, LRF and TOF/TOF)

Key Features:

Resolution: 26,000

mass range: up to 500,000

mass accuracy: 2 (int. calib.) (ppm)

laser: smartbeam II

laser frequency (Hz): 2,000 (MS)

TOF/TOF 2,000 (MS) 200 (TOF/TOF)

​

autoflex-maX.png

ultrafleXtreme

With increased resolution, larger mass range, enhanced dynamic range and patented smartbeam-II laser, the ultrafleXtreme provides outstanding MS and MS/MS spectral quality empowering polymer analysis. Unique PAN technology maintains the highest mass resolution across a very wide mass range to enable precision polymer analysis from average molecular weight determination, to dispersity and degree of polymerization analysis, and determination of end groups too. A highly extended MALDI laser lifetime in combination with automated laser-based source cleaning in just minutes leads to high uptime and minimum maintenance costs.

ultrafleXtreme TOF/TOF

Key Features:

Resolution: 40,000

mass range: up to 500,000

mass accuracy: 1,5 (int. calib.) (ppm)

laser: smartbeam II

laser frequency (Hz): 2,000 (MS)

TOF/TOF 1,000 (TOF/TOF)

ultrafleXtreme.png

rapidfleX series

The rapifleX® series is the most advanced and adaptable MALDI TOF(/TOF) system available. The rapifleX series combines state-of-the-art technology with advanced informatics into a system that gives you speed, robustness, and versatility. The mass resolving power of up to 50,000 and increased dynamic range provides confident determination in MALDI-TOF/TOF applications such as polymer end group analyses. With smartbeam 3D technology, MALDI MS and MS/ MS are up to 10 times faster for definitive polymer characterization and the ultimate in polymer deposition analysis. Adaptable ion optics allow for the best MALDI sensitivity in MS and MS/MS modes.

radipfleX (LRF and TOF/TOF)

Key Features:

Resolution: 50,000

mass range: up to 500,000

mass accuracy: 1 (int. calib.) (ppm)

laser: smartbeam 3D

laser frequency (Hz): 10,000 (MS)

TOF/TOF 10,000 (MS) & (TOF/TOF)

rapiflex-portrait.png
bottom of page